Skip to content

Our client asked:

How can oral consumer products be tested in a repeatable, representative way to accelerate the formulation of new products?

 

The project story:

  • We mapped client requirements to the key parameters needed to accurately reproduce oral conditions in a test rig
  • Using academic literature, we formulated a saliva analogue matching the chemical, physical and rheological characteristics of saliva. A representative oral cavity was designed to reflect open and saliva volumes that an oral consumer product would be exposed to during use
  • We built a fluidic system to sample saliva analogue from the cavity over time at a controlled rate and analyse release kinetics using a coupled flow spectrometer. This was then validated and calibrated against client released kinetics data
  • Once validated, the system supported the development of oral consumer products with novel active release profiles, significantly increasing development speed and enabling repeatable comparison of formulation iterations

 

Results: deliverables and outcomes

The client accelerated development of oral products while reducing reliance on consumer sensory trials. This enabled faster optimisation, improved product quality, and greater confidence in performance.

The test rig was subsequently adapted for use across additional product development programmes, extending its value across the organisation.

 

Need faster, more reliable ways to evaluate oral consumer products?

From bespoke testing platforms and physiologically relevant models to active release analysis, our scientists and engineers help organisations accelerate formulation development.